Measurement of the Half-Life of Orthopositronium

Thumbnail Image
Date
2004-05-01
Authors
Winter, Blake
Yuly, Mark
Journal Title
Journal ISSN
Volume Title
Publisher
Houghton College
Abstract
Until recently, measurements of the orthopositronium decay rate disagreed with the value predicted by quantum electrodynamics. This poster describes a novel attempt to measure this decay rate. Positrons from the decay of 22Na were slowed in a vacuum chamber containing a sample of aerogel. The release of a positron by the 22Na source was signaled by the detection of a 1.27 MeV gamma ray by a plastic scintillation detector. Orthopositronium typically decays into three gamma rays, which were detected by three NaI detectors. By detecting the annihilation gamma rays in coincidence and using energy information from the events, systematic effects due to contamination by parapositronium decay, which plagued previous measurements, may be reduced. Preliminary analysis of data taken over 200 hours has yielded a value for the decay rate of 7.83±0.5 μs-1. Currently, problems with Compton scattering are preventing the use of the energy information in analysis.
Description
Event
31st Annual Scientific Paper Session of the Rochester Academy of Science, Rochester, NY. Nov. 6, 2004
Keywords
Student Projects
Citation
Collections
Rights
Authors retain the copyright for all content posted in this repository. This material may not be published, reproduced, broadcast, rewritten, or redistributed beyond the Houghton College community without permission except in accordance with fair use doctrine.